Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Maxillofacial Plastic and Reconstructive Surgery ; : 22-2021.
Article in English | WPRIM | ID: wpr-918476

ABSTRACT

Background@#Foreign bodies may be embedded or left behind in the oral cavity during oral surgical procedure. The loss of instruments such as impression material, surgical gauze, and broken injection needles are commonly reported in the dental field. These complications are generally symptomatic and show signs of inflammation, pain, and purulent discharge. Accidental breakage of suture needles is a rare but potentially dangerous event.Case presentation: In this report, we present one case of lost suture needle during the procedure of flap operation at local dental clinic and its successful removal under local/general anesthesia administration via CBCT with a help of two reference needles to localize the 6-0 nylon needle and consulting with the clinician. @*Conclusion@#CT scanning taken while mouth-closing may not be accurate with regard to real location measurement performed while mouth-opening. If so, other up-to-date radiographic devices and methods to retrieve a needle are recommended.

2.
Journal of the Korean Association of Oral and Maxillofacial Surgeons ; : 58-65, 2020.
Article in English | WPRIM | ID: wpr-900723

ABSTRACT

Oroantral fistula (OAF), also termed oroantral communication, is an abnormal condition in which there is a communicating tract between the maxillary sinus and the oral cavity. The most common causes of this pathological communication are known to be dental implant surgery and extraction of posterior maxillary teeth. The purpose of this article is to describe OAF; introduce the approach algorithm for the treatment of OAF; and review the fundamental surgical techniques for fistula closure with their advantages and disadvantages. The author included a thorough review of the previous studies acquired from the PubMed database. Based on this review, this article presents cases of OAF patients treated with buccal flap, buccal fat pad (BFP), and palatal rotational flap techniques.

3.
Journal of the Korean Association of Oral and Maxillofacial Surgeons ; : 58-65, 2020.
Article in English | WPRIM | ID: wpr-811268

ABSTRACT

Oroantral fistula (OAF), also termed oroantral communication, is an abnormal condition in which there is a communicating tract between the maxillary sinus and the oral cavity. The most common causes of this pathological communication are known to be dental implant surgery and extraction of posterior maxillary teeth. The purpose of this article is to describe OAF; introduce the approach algorithm for the treatment of OAF; and review the fundamental surgical techniques for fistula closure with their advantages and disadvantages. The author included a thorough review of the previous studies acquired from the PubMed database. Based on this review, this article presents cases of OAF patients treated with buccal flap, buccal fat pad (BFP), and palatal rotational flap techniques.


Subject(s)
Humans , Adipose Tissue , Dental Implants , Fistula , Maxillary Sinus , Mouth , Oroantral Fistula , Tooth
4.
Journal of the Korean Association of Oral and Maxillofacial Surgeons ; : 58-65, 2020.
Article in English | WPRIM | ID: wpr-893019

ABSTRACT

Oroantral fistula (OAF), also termed oroantral communication, is an abnormal condition in which there is a communicating tract between the maxillary sinus and the oral cavity. The most common causes of this pathological communication are known to be dental implant surgery and extraction of posterior maxillary teeth. The purpose of this article is to describe OAF; introduce the approach algorithm for the treatment of OAF; and review the fundamental surgical techniques for fistula closure with their advantages and disadvantages. The author included a thorough review of the previous studies acquired from the PubMed database. Based on this review, this article presents cases of OAF patients treated with buccal flap, buccal fat pad (BFP), and palatal rotational flap techniques.

5.
Maxillofacial Plastic and Reconstructive Surgery ; : 54-2018.
Article in English | WPRIM | ID: wpr-918415

ABSTRACT

BACKGROUND@#The presence of septa increases the risk of Schneiderian membrane perforation during sinus lift procedure, and therefore, the chance of graft failure increases. We present a safe method of managing septa and, in particular, overcoming small and palatally located septa.@*METHODS@#After the elevation of the flap and the creation of a small bony window positioned anterior to the septum, the Schneiderian membrane is lifted carefully. A thin and narrow osteotome is then placed at the indentation created at the base of the septum, and mobilization of the septum is achieved by gentle malleting. The membrane is again carefully lifted up behind the septum.@*RESULTS@#There was one small membrane perforation case in all 16 cases, and none of these patients showed postoperative complications such as implant failure, infection, or maxillary sinusitis.@*CONCLUSIONS@#This technique is useful for overcoming the problem of maxillary sinus septa hindering the sinus floor elevation procedure, leading to fewer complications.

6.
Maxillofacial Plastic and Reconstructive Surgery ; : 34-2017.
Article in English | WPRIM | ID: wpr-122554

ABSTRACT

BACKGROUND: Patients who received orthodontic treatment are likely to have apical root shortening. It appears that external apical root resorption results from a combination of patient-related risk factors such as genetic influences, systemic factors, and orthodontic treatment-related factors. Regarding the fact that the anterior segmental osteotomy (ASO) has been known for its possibility of complementing external apical root resorption and of buffering periodontal problems, it has been the preferred treatment. However, the studies on the efficacy of ASO in preserving the root are not sufficient. In this study, we compared the amount of root resorption between the patients who only received orthodontic treatment and the patients who received orthodontic treatment with ASO. METHODS: This study included 28 patients (the number of incisor = 198) who received orthodontic treatment with or without ASO. We categorize them into groups A and B by the type of orthodontic treatment (group A: conventional orthodontic treatment; group B: orthodontic treatment with ASO). Cone-beam computed tomographic and cephalometric evaluations were retrospectively performed on the radiographs taken for the diagnosis of the treatment before treatment and at the end of active treatment. RESULTS: In group B, root resorption itself and its rate both turned out to have significantly lower than those in group A. Also, the change of incisal angle is significantly smaller in group B than in group A. On the other hand, in group A, the change of incisal angle was positively correlated with the change of AP (anteroposterior) position. In group B, the change of incisal angle was negatively correlated with the duration of the orthodontic treatment. In group B, amount of root resorption (mm) was positively correlated with the duration of the orthodontic treatment. CONCLUSIONS: The results show lesser root resorption and shorter treatment duration with ASO than with conventional orthodontic treatment. Therefore, if the indications are accurately determined, ASO can be an effective treatment option when the amount of root resorption is expected to be high, especially in late adults.


Subject(s)
Adult , Humans , Complement System Proteins , Cone-Beam Computed Tomography , Diagnosis , Hand , Incisor , Osteotomy , Retrospective Studies , Risk Factors , Root Resorption
7.
The Journal of Korean Academy of Prosthodontics ; : 303-309, 2007.
Article in English | WPRIM | ID: wpr-25866

ABSTRACT

STATEMENT OF PROBLEM: The effect of gold electroforming on gold alloy was not studied. PURPOSE: This in vitro study investigate the effect of gold electroforming on gold-silver-palladium alloy. MATERIAL AND METHODS: Three pieces of gold strips had undergone the electroforming procedures on one side and then half of the side again electroformed. The set mode for this study was program 1 (200 micrometer). And the processing time was 15min (1/20 time to form 200 micrometer coping). The confocal laser scanning microscope (PASCAL 5, Carl Zeiss, Bernried, Germany) was used to measure the thickness of the pure gold layer electroformed on the gold strips. Half of the gold strip was coated two times with electroformed gold, and the other half one time. The data from the cone focal laser system was processed to get the vertical profile of the strips and the difference of the vertical height between the double coated and single coated layer was regarded as the thickness of the gold coating. The layer thickness value to built 3D image of the cone-focal laser was set 0.5 micrometer. Next to the measurement of the thickness of the coating, the Vicker's hardness test was done. It was performed on the double coated surface, single coated surface and non-coated surface (back side) three times each. RESULTS: The mean thickness value gained from gold electroforming technique was measured to be 22 micrometer for sample 1, 23 micrometer for sample 2, 21 micrometer for sample 3. In the same condition of time, power and the amount of electrolyte, the data showed no difference between samples. According to the results of variance analysis, the differences among the variations in number of coating were statistically insignificant (p>0.05), meaning that the two times of gold electroforming coating did not change the hardness of gold-silver-palladium alloy. CONCLUSION: The test of thickness of gold coating proved the coherency of the gold electroforming procedure, in other words, when the power, the exposed surface area, processing time and the amount of electrolytes were set same, the same thickness of gold would be coated on. The hardness test showed that the electroformed gold coating did not change the hardness of the gold-silver-palladium alloy when it is coated not more than 45 micrometer.


Subject(s)
Alloys , Electrolytes , Hardness , Hardness Tests
8.
The Journal of Korean Academy of Prosthodontics ; : 765-781, 2000.
Article in English | WPRIM | ID: wpr-202090

ABSTRACT

The purpose of this study was to compare the screw loosening characteristics of three available cementation type abutments: one-piece cementation type abutment; two-piece cementation type abutment using titanium abutment screw; two-piece cementation type abutment using gold abutment screw. Two implant supported three-unit superstructures were fabricated using a pair of 3 kinds of abutments for each experimental model. Cyclic loading was applied on the specimen, and made to stop when the superstructure showed movement over threshold range. The loaded cycle was counted until the machine stopped. Frequency analysis was done to measure the change of natural frequency before and after the application of cyclic load and to find the effect of screw loosening on the change of natural frequency. The specimen assembly was modeled to perform the finite element analysis to see the distribution of the stress induced by the application of preload over the screw joint and to compare the pattern of the distribution of stress induced by the external force with the change of the preload condition. The following results were obtained: 1. The failure loading cycle of two-piece cementation type abutment using gold screw was significantly greater than those of the other groups. 2. One-piece cementation type abutment applied to multi-unit restoration case did not show greater resistance to screw loosening compared to two-piece cementation type abutments. 3. Frequency analysis showed decrease in natural frequency when screw loosening occured.


Subject(s)
Cementation , Finite Element Analysis , Joints , Models, Theoretical , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL